Each filter element is
sufficient for cleaning about 100 liters of clear water. If used daily, this
will last for about 4 to 6 weeks.
|
How to change the Cyst Filter: |
If the water flow gets weaker, you should change the Cyst Filter.
1. Turn the lid clockwise and lift it off together with the filter elements.
2. Using a slight turning motion, pull the Cyst Filter from the Virustat¨
cartridge
3. Using a slight turning motion, push the new Cyst Filter firmly, but
without excessive force, onto the Virustat¨
cartridge and make sure that the O-ring is seated correctly
4. To check, push the complete filter against the lid with a slight turning
motion until the filter sits firmly
5. Insert the complete filter into the bottle and turn the lid
anti-clockwise.
|
How to change the Virustat®
cartridge:
After filtering about 100 liters of water, it is usually time to change the
Virustat¨ cartridge. If used daily, this will be necessary after about 4 to
6 weeks.
1. Turn the lid clockwise and lift it off together with the filter elements.
2. Turn the Virustat¨ cartridge out of the Post Filter (any turning
direction)
3. Pull the Cyst Filter out of the Virustat¨ cartridge. A small twist may be
necessary.
4. Applying slight pressure and with a slight turning motion, connect the
new Virustat¨ cartridge to the Post Filter
and the Cyst Filter. Make sure that the O-rings are seated
correctly.
5. Push the complete filter against the lid until it sits firmly.
6. Turning anti-clockwise, screw the lid together with the complete filter
onto the bottle.
How to change the Post Filter
(activated carbon granulate):
If you detect a "chemical"
taste (iodine) or when changing the Virustat¨ cartridge,
the Post Filter should also be changed.
1. Turn the lid clockwise and lift it off together with the filter elements.
2. Twist and pull the complete filter out of the lid (any turning direction)
3. Pull the Post Filter off the end of the Virustat‚ cartridge.
4. Twist and push the new Post Filter against the Virustat¨ cartridge (any
turning direction), making sure that the
O-rings are seated correctly.
5. Push the complete filter against the lid (any turning direction). Follow
the steps under item 1 in "2) Important!
How to get the Katadyn Bottle ready for first time use".
Disposal:
The components of the Katadyn Bottle can be disposed together with the
normal domestic waste.
Caution:
The Virustat¨ cartridge contains iodine resin. Persons with iodine
allergies, thyroid problems and pregnant women should consult their doctor
before using the bottle. The Post Filter absorbs iodine, but traces of
iodine may be left in the water. Note: iodine is a natural substance and
important for the body in normal doses. This is why it is added to table
salt in most countries.
Active ingredients:
46% iodine. Even a water filter needs a little care and attention. If the
bottle is not used for three days or more, it must be cleaned and stored at
a dry place. If the bottle is not used for longer periods, allow the bottle
to air-dry out completely. Depending on temperature and air humidity, drying
may last between a few days and two
weeks. Drying prevents the filter from accumulating germs and forming
pathogens.
Storage:
Dismantle the filter stages. Pour out the water. Store the filter stages in
a dry and well ventilated place. The bottle (without filters) and the lid
(mouthpiece in the open position) can be cleaned in the dishwasher. Dry the
bottle and store it (with lid removed) next to the filter elements. It is
best to store the components in an open carton box to make sure that the
parts including the instructions stay together.
|